<address id="9tv9j"></address>

    <form id="9tv9j"><th id="9tv9j"><progress id="9tv9j"></progress></th></form>

    <address id="9tv9j"><address id="9tv9j"><nobr id="9tv9j"></nobr></address></address><noframes id="9tv9j"><listing id="9tv9j"><listing id="9tv9j"></listing></listing><noframes id="9tv9j"><form id="9tv9j"><nobr id="9tv9j"></nobr></form>

    <form id="9tv9j"></form>
    • Sonics ultrasonic processor
    • VCX500
    • Power: 500W, standard swing arm processing volume: 50ml to 250ml.
    • VCX500
    • Sonics ultrasonic processor
    • Power: 500W, standard swing arm processing volume: 50ml to 250ml.
    Sonics ultrasonic processor VCX500 can safely process various organic and inorganic materials, from 250 microliters to 1 liter*. Typical applications include nanotechnology (production of nanoparticle materials and graphene dispersions), cell lysis, sample preparation, homogenization, ChIP analysis, emulsification, disaggregation and deagglomeration, as well as applications in the field of ultrasonic liquid chemical processing.
    Product Introduction
    Sonics ultrasonic processor VCX500 can safely process various organic and inorganic materials, from 250 microliters to 1 liter*. Typical applications include nanotechnology (production of nanoparticle materials and graphene dispersions), cell lysis, sample preparation, homogenization, ChIP analysis, emulsification, disaggregation and deagglomeration, as well as applications in the field of ultrasonic liquid chemical processing.


    Product Features
    ◆ Programmable
    ◆ Variable power output
    ◆ 10-hour timer
    ◆ Pulse mode
    ◆ Power and energy display
    ◆ Temperature monitoring
    ◆ Energy setting value


    Experimental Objectives
    1. Understand the basic principles of ultrasonic cell disruption.
    2. Master the basic techniques of ultrasonic cell disruption.


    Principle of Experiment
    When strong sound waves act on a solution, the cavitation phenomenon of bubble generation, growth, and rupture is related. The shock waves and shear forces caused by cavitation phenomenon cause cell lysis.
    Materials and Reagents
    10ml bacteria, beaker, crushed ice, 75% alcohol cotton ball.


    Probe Selection  
    Probe Model and Size Cell Disruption Capacity
    2mm 150ul-5ml
    3mm 250ul-10ml
    6mm 10ml-50ml
    13mm 50ml-250ml


    Technical Specifications  
    Model: VCX 500
    Frequency: 20KHz
    Power: 500W
    Inverter Model: CV18
    Standard Amplitude Bar: Φ13mm
    Standard Amplitude Bar Length: 136mm
    Overall Dimension of Amplitude Bar: 235 x 190 x 340 mm
    Amplitude Bar Material: Titanium alloy Ti-6Al-4V
    Standard Amplitude Bar Processing Capacity: 50ml to 250ml
    Optional Amplitude Bars: Φ2mm, Φ6mm, Φ13mm
    Weight of the amplitude bar: 900g
    Length of the amplitude bar cable: 1.5m
    Duty cycle: 1-99%
    Power adjustment range: Continuously adjustable (20-500w)
    Interval time: 0.1-99.9s
    Temperature protection setting: Available, energy and temperature setpoint control (temperature probe needs to be added)
    Power amplitude display: Available
    Working frequency range: Digital wattmeter of energy monitor, automatic tuning and automatic amplitude compensation
    Working time: Microprocessor-based programmable 10-hour timer, 1-59 seconds independent/on-off pulse
    Ultrasonic time: From 1 second to 10 hours
    Working mode: Interval/continuous
    Power supply: 220/110V 50Hz/60Hz or, unless otherwise specified, the power requirements are sent at 117V, 50/60Hz
    Net weight: 6.8kg
    Main unit + transducer weight: 3680g
    Product List
    VCX500 Unit
    Host Machine Unit
    Toolbox set
    Power cord piece
    Soundproof box set
    Special Crushing Cup Piece
    Temperature sensor piece
    User manual copy
    Description
    1
    1
    1
    Optional
    Optional
    Optional
    1
    一区二区三区四区精品视频